19 results on '"Colozza N"'
Search Results
2. Nuovi elettrodi stampati paper-based per il monitoraggio dei processi degradativi del cemento armato
- Author
-
Arduini, F, Colozza, N, Sassolini, A, Mazzaracchio, V, Luca, F, Kersti, H, and MOSCONE DINIA, D
- Subjects
Settore CHIM/01 - Published
- 2019
3. Monitoraggio della corrosione nelle barre di rinforzo per le strutture in cemento armato
- Author
-
Arduini, F, Colozza, N, Sassolini, A, Abruzzese, D, Micheletti, A, and Tiero, A
- Subjects
corrosione ,cemento armato ,barre di armatura ,sensori elettrochimici ,Settore CHIM/01 ,Settore ICAR/08 - Published
- 2019
4. Electroanalysis moves towards paper-based printed electronics
- Author
-
Cinti, S., Colozza, N., Cacciotti, I., Moscone, D., Polomoshnov, M., Sowade, E., Baumann, R.R., Arduini, F., and Publica
- Abstract
Herein we demonstrated, for the first time, the possibility to use the paper employed in printed electronics (i.e. p_e:smart) as substrate to develop a paper-based sensor. To improve the electrochemical performances of the inkjet-printed sensor, a dispersion based on carbon black nanoparticles was used to modify the working electrode, allowing for a highly performant nanomodified electrochemical sensor platform. This disposable sensor was characterized both electrochemically and morphologically, and it has been successively challenged towards a model analyte namely ascorbic acid. It has been evidenced that the presence of carbon black as nanomodifier decreased the overpotential for ascorbic acid oxidation (from 0.47 V to 0.28 V) with respect to the unmodified sensor and boosted the sensitivity (ca. 3-times). The applicability of this printed electrochemical sensor was demonstrated for the detection of ascorbic acid in a dietary supplement, quantifying 999 ± 130 mg with respect to the 1000 mg reported on the label.
- Published
- 2018
5. Electroanalytical Sensor Based on Gold-Nanoparticle-Decorated Paper for Sensitive Detection of Copper Ions in Sweat and Serum
- Author
-
Simona Roggero, Neda Bagheri, Paolo A. Netti, Vincenzo Mazzaracchio, Stefano Cinti, Danila Moscone, Noemi Colozza, Mohammad Saraji, Fabiana Arduini, Concetta Di Natale, Bagheri, N., Mazzaracchio, V., Cinti, S., Colozza, N., Di Natale, C., Netti, P. A., Saraji, M., Roggero, S., Moscone, D., and Arduini, F.
- Subjects
Analyte ,Microfluidics ,Metal Nanoparticles ,Nanoparticle ,chemistry.chemical_element ,Nanotechnology ,Biosensing Techniques ,Standard solution ,010402 general chemistry ,01 natural sciences ,Analytical Chemistry ,law.invention ,Biosensing Technique ,law ,Ion ,Sweat ,Ions ,Filter paper ,010401 analytical chemistry ,Copper ,0104 chemical sciences ,chemistry ,Reagent ,Gold ,Atomic absorption spectroscopy - Abstract
The growth of (bio)sensors in analytical chemistry is mainly attributable to the development of affordable, effective, portable, and user-friendly analytical tools. In the field of sensors, paper-based devices are gaining a relevant position for their outstanding features including foldability, ease of use, and instrument-free microfluidics. Herein, a multifarious use of filter paper to detect copper ions in bodily fluids is reported by exploiting this eco-friendly material to (i) synthesize AuNPs without the use of reductants and/or external stimuli, (ii) print the electrodes, (iii) load the reagents for the assay, (iv) filter the gross impurities, and (v) preconcentrate the target analyte. Copper ions were detected down to 3 ppb with a linearity up to 400 ppb in standard solutions. The applicability in biological matrices, namely, sweat and serum, was demonstrated by recovery studies and by analyzing these biofluids with the paper-based platform and the reference method (atomic absorption spectroscopy), demonstrating satisfactory accuracy of the novel eco-designed analytical tool.
- Published
- 2021
6. A challenge in biosensors: Is it better to measure a photon or an electron for ultrasensitive detection?
- Author
-
Patrizia Simoni, Martina Zangheri, Elisa Marchegiani, Laura Fabiani, Aldo Roda, Noemi Colozza, Danila Moscone, Mara Mirasoli, Fabiana Arduini, Roda A., Arduini F., Mirasoli M., Zangheri M., Fabiani L., Colozza N., Marchegiani E., Simoni P., and Moscone D.
- Subjects
Chemiluminescence ,Biomedical Engineering ,Biophysics ,Amperometry ,Reproducibility of Result ,Nanotechnology ,Electrons ,02 engineering and technology ,Biosensing Techniques ,Immunosensor ,Electron ,01 natural sciences ,Horseradish peroxidase ,Sensitivity and Specificity ,law.invention ,Biosensing Technique ,Settore CHIM/01 ,law ,Electrochemistry ,Electrochemical biosensor ,Enzyme-based biosensor ,Photons ,Electrochemical Technique ,biology ,Chemistry ,Paper-based assay ,010401 analytical chemistry ,Reproducibility of Results ,General Medicine ,Electrochemical Techniques ,021001 nanoscience & nanotechnology ,Photon ,0104 chemical sciences ,Luminescent Measurement ,Luminescent Measurements ,biology.protein ,0210 nano-technology ,Biosensor ,Biotechnology - Abstract
Biosensor development exploiting various transduction principles is characterized by a strong competition to reach high detectability, portability and robustness. Nevertheless, a literature-based comparison is not possible, as different conditions are employed in each paper. Herein, we aim at evaluating which measurement, photons or electrons, yields better biosensor performance. Upon outlining an update in recent achievements to boost analytical performance, amperometry and chemiluminescence (CL)-based biosensors are directly compared employing the same biospecific reagents and analytical formats. Horseradish peroxidase (HRP) and hydrogen peroxide concentrations were directly measured, while glucose and mouse IgG were detected employing an enzyme paper-based biosensor and an immunosensor, respectively. Detectability was down to picomoles of hydrogen peroxide (4 pmol for CL and 210 pmol for amperometry) and zeptomoles of HRP (45 zmol for CL and 20 zmol for amperometry); IgG was detected down to 12 fM (CL) and 120 fM (amperometry), while glucose down to 17 μM (CL) and 40 μM (amperometry). Results showed that amperometric and CL biosensors offered similar detectability and analytical performance, with some peculiarities that suggest complementary application fields. As they generally provided slightly higher detectability and wider dynamic ranges, CL-based biosensors appear more suitable for point-of-care testing of clinical biomarkers, where detectability is crucial. Nevertheless, as high detectability in CL biosensors usually requires longer acquisition times, their rapidity will allocate electrochemical biosensors in real-time monitoring and wearable biosensors. The analytical challenge demonstrated that these biosensors have competitive and similar performance, and between photons and electrons the competition is still open.
- Published
- 2019
7. Electroanalysis moves towards paper-based printed electronics: carbon black nanomodified inkjet-printed sensor for ascorbic acid detection as a case study
- Author
-
Reinhard R. Baumann, Enrico Sowade, Danila Moscone, Fabiana Arduini, Ilaria Cacciotti, Stefano Cinti, Maxim Polomoshnov, Noemi Colozza, Cinti, S., Colozza, N., Cacciotti, I., Moscone, D., Polomoshnov, M., Sowade, E., Baumann, R. R., and Arduini, F.
- Subjects
Analyte ,Materials science ,Working electrode ,Nanotechnology ,02 engineering and technology ,Substrate (printing) ,Overpotential ,01 natural sciences ,Paper-based sensor ,Electroanalysi ,Carbon black ,Materials Chemistry ,Ascorbic acidCarbon blackElectroanalysisInkjet printingPaper-based sensorsPrinted electronics ,Settore CHIM/01 - Chimica Analitica ,Electrical and Electronic Engineering ,Instrumentation ,010401 analytical chemistry ,Metals and Alloys ,Printed electronics ,021001 nanoscience & nanotechnology ,Condensed Matter Physics ,Ascorbic acid ,0104 chemical sciences ,Surfaces, Coatings and Films ,Electronic, Optical and Magnetic Materials ,Electrochemical gas sensor ,Inkjet printing ,0210 nano-technology - Abstract
Herein we demonstrated, for the first time, the possibility to use the paper employed in printed electronics (i.e. p_e:smart) as substrate to develop a paper-based sensor. To improve the electrochemical performances of the inkjet-printed sensor, a dispersion based on carbon black nanoparticles was used to modify the working electrode, allowing for a highly performant nanomodified electrochemical sensor platform. This disposable sensor was characterized both electrochemically and morphologically, and it has been successively challenged towards a model analyte namely ascorbic acid. It has been evidenced that the presence of carbon black as nanomodifier decreased the overpotential for ascorbic acid oxidation (from 0.47 V to 0.28 V) with respect to the unmodified sensor and boosted the sensitivity (ca. 3-times). The applicability of this printed electrochemical sensor was demonstrated for the detection of ascorbic acid in a dietary supplement, quantifying 999 ± 130 mg with respect to the 1000 mg reported on the label.
- Published
- 2018
8. Paper-Based Electrochemical (Bio)Sensors for the Detection of Target Analytes in Liquid, Aerosol, and Solid Samples.
- Author
-
Colozza N, Mazzaracchio V, and Arduini F
- Abstract
The last decade has been incredibly fruitful in proving the multifunctionality of paper for delivering innovative electrochemical (bio)sensors. The paper material exhibits unprecedented versatility to deal with complex liquid matrices and facilitate analytical detection in aerosol and solid phases. Such remarkable capabilities are feasible by exploiting the intrinsic features of paper, including porosity, capillary forces, and its easy modification, which allow for the fine designing of a paper device. In this review, we shed light on the most relevant paper-based electrochemical (bio)sensors published in the literature so far to identify the smart functional roles that paper can play to bridge the gap between academic research and real-world applications in the biomedical, environmental, agrifood, and security fields. Our analysis aims to highlight how paper's multifarious properties can be artfully harnessed for breaking the boundaries of the most classical applications of electrochemical (bio)sensors.
- Published
- 2024
- Full Text
- View/download PDF
9. Paper as smart support for bioreceptor immobilization in electrochemical paper-based devices.
- Author
-
Seddaoui N, Colozza N, Gullo L, and Arduini F
- Subjects
- Molecularly Imprinted Polymers, Antibodies, Engineering, Electrochemical Techniques, Biosensing Techniques
- Abstract
The use of paper as a smart support in the field of electrochemical sensors has been largely improved over the last 15 years, driven by its outstanding features such as foldability and porosity, which enable the design of reagent and equipment-free multi-analysis devices. Furthermore, the easy surface engineering of paper has been used to immobilize different bioreceptors, through physical adsorption, covalent bonding, and electrochemical polymerization, boosting the fine customization of the analytical performances of paper-based biosensors. In this review, we focused on the strategies to engineer the surface of the paper for the immobilization of (bio)recognition elements (eg., enzymes, antibodies, DNA, molecularly imprinted polymers) with the overriding goal to develop accurate and reliable paper-based electrochemical biosensors. Furthermore, we highlighted how to take advantage of paper for designing smart configurations by integrating different analytical processes in an eco-designed analytical tool, starting from the immobilization of the (bio)receptor and the reagents, through a designed sample flow along the device, until the analyte detection., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2023 The Authors. Published by Elsevier B.V. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
10. Nanomaterials and paper-based electrochemical devices: merging strategies for fostering sustainable detection of biomarkers.
- Author
-
Caratelli V, Di Meo E, Colozza N, Fabiani L, Fiore L, Moscone D, and Arduini F
- Subjects
- Reproducibility of Results, Biomarkers, Cellulose, Nanostructures chemistry, Biosensing Techniques
- Abstract
In the last few decades, nanomaterials have made great advances in the biosensor field, thanks to their ability to enhance several key issues of biosensing analytical tools, namely, sensitivity, selectivity, robustness, and reproducibility. The recent trend of sustainability has boosted the progress of novel and eco-designed electrochemical paper-based devices to detect easily the target analyte(s) with high sensitivity in complex matrices. The huge attention given by the scientific community and industrial sectors to paper-based devices is ascribed to the numerous advantages of these cost-effective analytical tools, including the absence of external equipment for solution flow, thanks to the capillary force of paper, the fabrication of reagent-free devices, because of the loading of reagents on the paper, and the easy multistep analyses by using the origami approach. Besides these features, herein we highlight the multifarious aspects of the nanomaterials such as (i) the significant enlargement of the electroactive surface area as well as the area available for the desired chemical interactions, (ii) the capability of anchoring biorecognition elements on the electrode surface on the paper matrix, (iii) the improvement of the conductivity of the cellulose matrix, (iv) the functionality of photoelectrochemical properties within the cellulose matrix, and (v) the improvement of electrochemical capabilities of conductive inks commonly used for electrode printing on the paper support, for the development of a new generation of paper-based electrochemical biosensors applied in the biomedical field. The state of the art over the last ten years has been analyzed highlighting the various functionalities that arise from the integration of nanomaterials with paper-based electrochemical biosensors for the detection of biomarkers.
- Published
- 2022
- Full Text
- View/download PDF
11. An origami paper-based electrochemical biosensing platform for quality control of agri-food waste in the valorization strategy.
- Author
-
Colozza N, Di Meo E, Mucaria A, Moscone D, and Arduini F
- Subjects
- Food, Glucose, Paper, Quality Control, Glucosinolates, Refuse Disposal
- Abstract
The increasing demand for food and the need for a sustainability vision in the agri-food sector have boosted novel approaches for food management, enhancing the valorization of wastes and by-products belonging to the food industry. Herein, we present a novel paper-based origami device to assess the amount of both glucosinolate and glucose in a food waste product belonging to Brassicaceae plants, to evaluate the quality value and the correct management of waste samples. The device has been designed as an origami paper-based platform constituted of two paper-based biosensors to work synergistically in a multiplexed detection. In detail, a monoenzymatic biosensor and a bienzymatic biosensor were configured for the detection of glucose and glucosinolates, respectively, using filter paper pads preloaded with glucose oxidase and/or myrosinase. To complete the paper-based platform, the enzyme-preloaded pads were combined with office paper-based electrodes modified with Carbon black/Prussian Blue nanoparticles for the measurement of enzymatic by-product at a low applied potential (i.e., 0 V versus Ag/AgCl). Overall, this paper-based platform measured glucose and glucosinolate (i.e., sinigrin) with a linear range up to 2.5 and 1.5 mM, and detection limits of 0.05 and 0.07 mM, respectively. The repeatability corresponded to an RSD% equal to 5% by testing 10 mM of glucose, and 10% by testing 1 mM of sinigrin. The accuracy of the developed multiplex device was evaluated by recovery studies at two different levels of sinigrin, i.e., 0.25 and 0.5 mM, obtaining recoveries values equal to (111 ± 3) % and (86 ± 1) %, respectively. The multiplex detection of both glucose and glucosinolate in Brassicaceae samples evaluates the quality values of the waste sample, ensuring the quality of the re-used food product waste by using an eco-designed analytical tool. The combination of paper-based devices for quality control of food waste with the re-use of these food products represents a sustainable approach that perfectly matches sustainable agrifood practices as well as the overall approach of the circular economy., (© 2022. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF
12. Vertical-Flow Paper Sensor for On-Site and Prompt Evaluation of Chloride Contamination in Concrete Structures.
- Author
-
Colozza N, Tazzioli S, Sassolini A, Agosta L, di Monte MG, Hermansson K, and Arduini F
- Abstract
Corrosion occurring in reinforced concrete has turned into a primary concern of the current century, concrete being the most ubiquitous and predominant material used in the construction industry. Among the many interrelated processes that trigger corrosion of metallic reinforcements, the penetration of chloride ions into the concrete matrix is the most insidious threat. Herein, we developed the first electrochemical device entirely made of paper that allows for the direct, prompt, and noninvasive evaluation of free chloride ion contamination in concrete-based constructions. Our device is based on a three-layer wax-modified filter paper, consisting of two Ag/AgCl screen-printed electrodes that are interfaced by a junction pad in a sandwich-like configuration. Filter paper allows for generating a vertical-flow potentiometric device capable of measuring the electrochemical potential between two solutions containing different concentrations of chloride ions, which are separately drop-cast on the top and bottom layers. After demonstrating the analytical performance of the device, the same principle was applied to the evaluation of the chloride contents in different concrete samples, exploiting paper as a suitable interfacing material for potentiometric measurements on the cement solid surface. Laboratory-prepared concrete samples with known chloride contents were first assessed, and then, the paper-based vertical-flow device was applied to real concrete structures at the Giacomo Manzù Museum (Ardea, Italy) for the evaluation of chloride contamination caused by the proximity to the seaside. The capability of our device to provide timely warning of the risk conditions of concrete-based artifacts was demonstrated.
- Published
- 2021
- Full Text
- View/download PDF
13. Origami Paper-Based Electrochemical (Bio)Sensors: State of the Art and Perspective.
- Author
-
Colozza N, Caratelli V, Moscone D, and Arduini F
- Subjects
- Electrodes, Biosensing Techniques, Electrochemical Techniques, Paper
- Abstract
In the last 10 years, paper-based electrochemical biosensors have gathered attention from the scientific community for their unique advantages and sustainability vision. The use of papers in the design the electrochemical biosensors confers to these analytical tools several interesting features such as the management of the solution flow without external equipment, the fabrication of reagent-free devices exploiting the porosity of the paper to store the reagents, and the unprecedented capability to detect the target analyte in gas phase without any sampling system. Furthermore, cost-effective fabrication using printing technologies, including wax and screen-printing, combined with the use of this eco-friendly substrate and the possibility of reducing waste management after measuring by the incineration of the sensor, designate these type of sensors as eco-designed analytical tools. Additionally, the foldability feature of the paper has been recently exploited to design and fabricate 3D multifarious biosensors, which are able to detect different target analytes by using enzymes, antibodies, DNA, molecularly imprinted polymers, and cells as biocomponents. Interestingly, the 3D structure has recently boosted the self-powered paper-based biosensors, opening new frontiers in origami devices. This review aims to give an overview of the current state origami paper-based biosensors, pointing out how the foldability of the paper allows for the development of sensitive, selective, and easy-to-use smart and sustainable analytical devices.
- Published
- 2021
- Full Text
- View/download PDF
14. Paper-based electrochemical sensor for on-site detection of the sulphur mustard.
- Author
-
Colozza N, Kehe K, Popp T, Steinritz D, Moscone D, and Arduini F
- Subjects
- Electrochemical Techniques, Electrodes, Hydrogen Peroxide, Limit of Detection, Biosensing Techniques, Mustard Gas, Nanoparticles
- Abstract
Herein, we report a novel paper-based electrochemical sensor for on-site detection of sulphur mustards. This sensor was conceived combining office paper-based electrochemical sensor with choline oxidase enzyme to deliver a sustainable sensing tool. The mustard agent detection relies on the evaluation of inhibition degree of choline oxidase, which is reversibly inhibited by sulphur mustards, by measuring the enzymatic by-product H
2 O2 in chronoamperometric mode. A nanocomposite constituted of Prussian Blue nanoparticles and Carbon Black was used as working electrode modifier to improve the electroanalytical performances. This bioassay was successfully applied for the measurement of a sulphur mustard, Yprite, obtaining a detection limit in the millimolar range (LOD = 0.9 mM). The developed sensor, combined with a portable and easy-to-use instrumentation, can be applied for a fast and cost-effective detection of sulphur mustards.- Published
- 2021
- Full Text
- View/download PDF
15. Electroanalytical Sensor Based on Gold-Nanoparticle-Decorated Paper for Sensitive Detection of Copper Ions in Sweat and Serum.
- Author
-
Bagheri N, Mazzaracchio V, Cinti S, Colozza N, Di Natale C, Netti PA, Saraji M, Roggero S, Moscone D, and Arduini F
- Subjects
- Copper, Gold, Ions, Sweat, Biosensing Techniques, Metal Nanoparticles
- Abstract
The growth of (bio)sensors in analytical chemistry is mainly attributable to the development of affordable, effective, portable, and user-friendly analytical tools. In the field of sensors, paper-based devices are gaining a relevant position for their outstanding features including foldability, ease of use, and instrument-free microfluidics. Herein, a multifarious use of filter paper to detect copper ions in bodily fluids is reported by exploiting this eco-friendly material to (i) synthesize AuNPs without the use of reductants and/or external stimuli, (ii) print the electrodes, (iii) load the reagents for the assay, (iv) filter the gross impurities, and (v) preconcentrate the target analyte. Copper ions were detected down to 3 ppb with a linearity up to 400 ppb in standard solutions. The applicability in biological matrices, namely, sweat and serum, was demonstrated by recovery studies and by analyzing these biofluids with the paper-based platform and the reference method (atomic absorption spectroscopy), demonstrating satisfactory accuracy of the novel eco-designed analytical tool.
- Published
- 2021
- Full Text
- View/download PDF
16. Why ammonium detection is particularly challenging but insightful with ionophore-based potentiometric sensors - an overview of the progress in the last 20 years.
- Author
-
Cuartero M, Colozza N, Fernández-Pérez BM, and Crespo GA
- Abstract
The monitoring of ammonium ion concentration has gained the attention of researchers from multiple fields since it is a crucial parameter with respect to environmental and biomedical applications. For example, ammonium is considered to be a quality indicator of natural waters as well as a potential biomarker of an enzymatic byproduct in key physiological reactions. Among the classical analytical methods used for the detection of ammonium ions, potentiometric ion-selective electrodes (ISEs) have attracted special attention in the scientific community because of their advantages such as cost-effectiveness, user-friendly features, and miniaturization ability, which facilitate easy portable measurements. Regarding the analytical performance, the key component of ISEs is the selective receptor, labelled as an ionophore in ISE jargon. Indeed, the preference of an ionophore for ammonium amongst other ions (i.e., selectivity) is a factor that primarily dictates the limit of detection of the electrode when performing measurements in real samples. A careful assessment of the literature for the last 20 years reveals that nonactin is by far the most employed ammonium ionophore to date. Despite the remarkable cross-interference of potassium over the ammonium response of nonactin-based ISEs, analytical applications comprising water quality assessment, clinical tests in biological fluids, and sweat monitoring during sports practice have been successfully researched. Nevertheless, there is evident difficulty in the determination of close-to-micromolar levels of ammonium in real samples with a significant potassium background level (i.e., millimolar concentration). This fact has fostered the search for a large variety of ammonium ionophores over the years, which are critically inspected herein. Overall, we provide an easily readable state of the art accompanied by a comprehensive description of other types of ammonium electrodes, including commercially available units. We conclude that newer breakthroughs are still required in the field to reach the desired analytical applications.
- Published
- 2020
- Full Text
- View/download PDF
17. A challenge in biosensors: Is it better to measure a photon or an electron for ultrasensitive detection?
- Author
-
Roda A, Arduini F, Mirasoli M, Zangheri M, Fabiani L, Colozza N, Marchegiani E, Simoni P, and Moscone D
- Subjects
- Electrochemical Techniques methods, Electrochemical Techniques standards, Electrochemistry methods, Electrochemistry standards, Electrons, Luminescent Measurements methods, Luminescent Measurements standards, Photons, Reproducibility of Results, Sensitivity and Specificity, Biosensing Techniques methods, Biosensing Techniques standards
- Abstract
Biosensor development exploiting various transduction principles is characterized by a strong competition to reach high detectability, portability and robustness. Nevertheless, a literature-based comparison is not possible, as different conditions are employed in each paper. Herein, we aim at evaluating which measurement, photons or electrons, yields better biosensor performance. Upon outlining an update in recent achievements to boost analytical performance, amperometry and chemiluminescence (CL)-based biosensors are directly compared employing the same biospecific reagents and analytical formats. Horseradish peroxidase (HRP) and hydrogen peroxide concentrations were directly measured, while glucose and mouse IgG were detected employing an enzyme paper-based biosensor and an immunosensor, respectively. Detectability was down to picomoles of hydrogen peroxide (4 pmol for CL and 210 pmol for amperometry) and zeptomoles of HRP (45 zmol for CL and 20 zmol for amperometry); IgG was detected down to 12 fM (CL) and 120 fM (amperometry), while glucose down to 17 μM (CL) and 40 μM (amperometry). Results showed that amperometric and CL biosensors offered similar detectability and analytical performance, with some peculiarities that suggest complementary application fields. As they generally provided slightly higher detectability and wider dynamic ranges, CL-based biosensors appear more suitable for point-of-care testing of clinical biomarkers, where detectability is crucial. Nevertheless, as high detectability in CL biosensors usually requires longer acquisition times, their rapidity will allocate electrochemical biosensors in real-time monitoring and wearable biosensors. The analytical challenge demonstrated that these biosensors have competitive and similar performance, and between photons and electrons the competition is still open., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2020 Elsevier B.V. All rights reserved.)
- Published
- 2020
- Full Text
- View/download PDF
18. A wearable origami-like paper-based electrochemical biosensor for sulfur mustard detection.
- Author
-
Colozza N, Kehe K, Dionisi G, Popp T, Tsoutsoulopoulos A, Steinritz D, Moscone D, and Arduini F
- Subjects
- Aerosols analysis, Alcaligenes enzymology, Alcohol Oxidoreductases chemistry, Electrochemical Techniques instrumentation, Enzymes, Immobilized chemistry, Equipment Design, Humans, Limit of Detection, Paper, Biosensing Techniques instrumentation, Chemical Warfare Agents analysis, Mustard Gas analysis, Wearable Electronic Devices
- Abstract
The synthesis and employment of volatile toxic compounds as chemical weapons with a large-scale destructive power has introduced a new insidious threat over the last century. In this framework, the development of wearable sensing tools represents a critical point within the security field, in order to provide early alarm systems. Herein, a novel wearable electrochemical biosensor was developed for the rapid and on-site detection of mustard agents. Since a chemical attack is typically carried out by spraying these volatile agents into air, the sensor was designed in order to be able to measure mustard agents directly in the aerosol phase, further than in the liquid phase. The electrodes were screen-printed onto a filter paper support, which allowed to harness the porosity of paper to pre-load all the needed reagents into the cellulose network, and hence to realise an origami-like and reagent-free device. Mustard agent detection was carried out by monitoring their inhibitory effects toward the choline oxidase enzyme, through the amperometric measurement of the enzymatic by-product hydrogen peroxide. A carbon black/Prussian blue nanocomposite was used as a bulk-modifier of the conductive graphite ink constituting the working electrode, allowing for the electrocatalysis of the hydrogen peroxide reduction. After having verified the detecting capability toward a mustard agent simulant, the applicability of the resulting origami-like biosensor was demonstrated for the rapid and real-time detection of real sulfur mustard, obtaining limits of detection equal to 1 mM and 0.019 g·min/m
3 for liquid and aerosol phase, respectively., (Copyright © 2019 Elsevier B.V. All rights reserved.)- Published
- 2019
- Full Text
- View/download PDF
19. A miniaturized bismuth-based sensor to evaluate the marine organism Styela plicata bioremediation capacity toward heavy metal polluted seawater.
- Author
-
Colozza N, Gravina MF, Amendola L, Rosati M, Akretche DE, Moscone D, and Arduini F
- Subjects
- Animals, Biodegradation, Environmental, Cadmium isolation & purification, Electrodes, Lead isolation & purification, Bismuth, Metals, Heavy isolation & purification, Seawater chemistry, Urochordata, Water Pollutants, Chemical isolation & purification
- Abstract
Cadmium and lead are highly toxic heavy metals which cause a severe worldwide pollution. In addition to the toxic effect produced by the direct exposure, they can be bioconcentrated and accumulated in living organisms, including humans. Herein, a miniaturized and disposable electrochemical sensor was improved for the simultaneous detection of cadmium and lead ions to study the bioremediation of polluted seawater in presence of the filter-feeding marine organism Styela plicata. A screen-printed electrode modified in situ with a bismuth film was selected using the anodic stripping analysis as detection technique. This sensor was coupled with a portable potentiostat and the detection of cadmium and lead ions was carried out by Square Wave Anodic Stripping Voltammetry, allowing the simultaneous detection of both heavy metals at ppb level (LOD=0.3ppb for lead, 1.5ppb for cadmium). This analytical tool was then applied to assess the bioremediation capacity of S. plicata through a bioremediation experiment, in which the organism has been exposed to seawater artificially polluted with 1000ppb of Cd
2+ and Pb2+ . The matrix effect of both seawater and acid digested biological samples was evaluated. A bioconcentration phenomenon was observed for both heavy metals through the analysis of S. plicata tissues. In details, Pb2+ resulted to be about 2.5 times more bioconcentrated than Cd2+ , giving an effective bioremediation level in seawater of 13% and 40% for Cd2+ and Pb2+ , respectively. Thus, our results demonstrate the capability of S. plicata to bioremediate Cd2+ and Pb2+ polluted seawater as well as the suitability of the electrochemical sensor for contaminated marine environment monitoring and bioremediation evaluation., (Copyright © 2017 Elsevier B.V. All rights reserved.)- Published
- 2017
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.